JR Direct Radio XP662 User Manual Page 69

  • Download
  • Add to my manuals
  • Print
  • Page
    / 88
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 68
69
XP662 MANUAL Helicopter
CHAPTER 7: FUNCTIONS (FUNCTION MODE)
Helicopter
Programmable exponential adjustments are offered
on the aileron and elevator channels of your XP662
system. Exponential is a function that allows you to
tailor the response rate of the controls as compared
to the stick inputs. The purpose of exponential is to
reduce the sensitivity in the middle portion of stick
movement, while still allowing full travel at the end
of the stick movement. In other words, the end result
(travel) remains the same, although exponential
changes the rate at which it achieves this travel.
The adjustable range of the Exponential function is
from 0–100%. Zero percent (0%) is linear stick
control which means that the response rate is equal
throughout the stick control. One hundred percent
(100%) is full exponential. The larger the exponential
value, the less servo action, or sensitivity, you will
notice around the neutral setting.
Note: The Exponential function operates in
conjunction with the Dual Rate function. It is
imperative to understand the Dual Rate Function
prior to adjusting the exponential values.
Exponential may be selected independently for
either the high or low rate (position 0 or 1) or both.
EXPONENTIAL
7.3
Accessing the Exponential Function
1. Turn on the transmitter.
2. Press the SCROLL and INCREASE buttons
simultaneously to enter the Function mode.
3. Press the SCROLL button until “EXP” appears at
the left side of the screen.
4. Press the CHANNEL button until the desired
channel appears on the screen (AI or EL).
5. Using the appropriate dual rate switch, select
the correct position to be adjusted (0 or 1).
6. Press the INCREASE or DECREASE buttons to
increase/decrease the exponential value.
7. Press the SCROLL button to access the
Sub-Trim function.
8. To exit, press the SCROLL and INCREASE
buttons simultaneously.
SWITCH POSITION
AI = AILERON
EL = ELEVATOR
EXPONENTIAL VALUE
0
%
AIO
Press the INCREASE or
DECREASE buttons to
increase/decrease the
exponential valve (0100%).
Press the SCROLL button
until EXP appears on the
left side of the screen.
Note: The dual rate switch position is
changed/ accessed by setting the appropriate
dual rate switch to the 0 or 1 positions.
Press the CHANNEL button
to select either aileron or
elevator exponential.
EXP
A good starting point
for exponential valve is
approximately 2030%.
CHANNEL
SCROLL
INCREASE
DECREASE
ENTER
Page view 68
1 2 ... 64 65 66 67 68 69 70 71 72 73 74 ... 87 88

Comments to this Manuals

No comments